Description
GENERAL DESCRIPTION:
This evaluation board is designed to test and characterize the Innowave INL300 Low-Noise Amplifier module. It provides a complete test platform that allows customers to evaluate the INL300’s performance before proceeding with volume production integration.
FEATURES:
The evaluation board maintains the core specifications of the INL300 module while providing additional testing capabilities:
- Optimized RF layout for maximum performance
- High-quality SMA connectors for reliable RF connections
- Multiple test points for performance verification
- Ground plane optimization for minimal noise
- Thermal management considerations
- Single low positive supply
TECHNICAL SPECIFICATIONS:
- High gain:
- 20 dB to 22dB at 1.43 GHz to 2.81 GHz
- Gain: > 15dB at 1.01 GHz to 4.16 GHz
- Gain: > 12dB at 923 MHz to 6.28 GHz
- Gain: > 10dB at 832 MHz to 6.64 GHz
- Gain: > 8dB at 751 MHz to 6.99 GHz
- High OIP3:
- 9 dBm at 2.45 GHz
- Low noise figure:
- 63 dB – 0.64 dB at 2.4 GHz to 2.5 GHz
- 63 dB – 0.95 dB at 1.01 GHz to 4.16 GHz
- OIP3 is 14.4 dBm to 14.9 dBm at 2.4 GHz to 2.5 GHz
- Drain efficiency:
- > 15 % at 2.28 GHz to 5.44 GHz with an input power of 5 dBm
- Size: 4.765mm x 4.580mm
- Low Noise Figure and Reliable
- 20 dB to 22dB at 1.43 GHz to 2.81 GHz
BOARD COMPONENTS:
The evaluation board includes:
- INL300 LNA module mounting area
- Power supply filtering and bypass capacitors
- Multiple ground test points
- Power supply terminal blocks
SPECIFICATION:Parameter Min Typ Max Unit Test Condition Frequency Range 0.75 6.99 GHz Gain 8 22 dB Noise Figure 0.634 2.495 dB Input Return Loss -2.1 -13.9 dB Output Return Loss -0.6 -18.7 dB Output 1dB Compression Power (OP1dB) 9 dBm Freq = 5 GHz
USER GUIDELINES:
- RF Connections
- Use high-quality RF cables with proper torque specifications
- Ensure proper connection of input/output SMA connectors
- Power Supply Connection
- Connect a clean DC power supply within the specified voltage range
- Verify proper voltage at test points before mounting the LNA
- Testing Recommendations
- Allow sufficient warm-up time for stable operation
- Follow standard RF measurement practices
- Monitor power supply current during operation
- Observe maximum input power specifications